The Particles Plus® 8301-AQM1 and 8301-AQM2 Series Handheld Particle Counter and Environmental Monitor measures 0.3 to 25 μm particles with mass concentration and stores indoor air quality measurements of temperature, relative humidity, CO2, and TVOC in the 8301-AQM2. This instrument is the most versatile handheld Air Monitor available, with advanced power management and the industry’s first sleep mode, allowing for battery operation of periods that can exceed a month on a single charge. The AQM Series can be used as a stand-alone battery operated instrument or it can be easily integrated into a building automation and facility monitoring system via Ethernet, USB or (optional) Wireless 802.11 b/g, RS485 or RS232 connection.
Model | 8301-AQM1 and 8301-AQM2 |
Size Range | 0.3 to 25 μm |
Size Channels | Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm variable binning |
Flow rates / Accuracy | 0.1 CFM (2.83 LPM) / ± 3% or 1.2 LPM ± 3% |
Aerosol Concentration Range | 0.01 to 20,000 μg/m³ |
Light Source | Long life laser diode |
Resolution | 0.00003 μg/m3 |
Zero Stability | No appreciable drift |
Count Modes | Real-Time Meter and graph, cumulative/differential count/m³ and count/ft³, and mass concentration (PM) |
Log Interval | Minimum 1 second with no hold time, maximum 99 hours |
Calibration | NIST traceable |
Display | 4.3″ (10.9 cm) WQVGA (480×272) color touch screen |
Printer | (Optional) External thermal printer available |
Vacuum Source | Internal pump with automatic flow control |
Filtered Exhaust | Internal HEPA filter |
Number of Channels | 6 |
Custom Size Channels | Calibration for custom size channels available |
Audible Alarm | Adjustable built-in alarm |
Communication Modes | Ethernet, USB. (Optional) Wireless 802.11 b/g, RS485 or RS232. |
Environmental Sensors 8301-AQM1 | Includes NDIR CO2 (0-5000 ppm, resolution 1 ppm, accuracy ±1% FS, Response rate 20 seconds), temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% RH |
Environmental Sensors 8301-AQM2 | Includes all sensors in the 8301-AQM1 and TVOC PID (standard on the 8301-AQM2), 0-50 ppm / minimum detection level 5 ppb, accuracy ±1.5%, Response rate <3 seconds |
Alarm | Alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow |
Standards | ISO 21501-4 and JIS B9921 |
Instrument Calibration | Recommended minimum once per year. Gases, temperature and humidity sensors field calibratable. |
External Surface | Lightweight high-impact injection molded plastic enclosure |
Dimensions (L x W x H) | 6.33” x 4.25” x 12.26” (16.1 cm x 10.8 cm x 31.1 cm) includes handle and does not include probes |
Weight | 2.5 lb (1.1 kg) |
Accessories | Operating manual and IMS software on USB flash drive, isokinetic probe, temperature relative humidity sensor, purge filter, battery, data download software, USB cable, power supply and cable |
Optional Accessories | Printed manual, carrying case, spare battery, external battery charger, external printer and isokinetic probes, barbed fittings, IMS-RT monitoring system |
Data Storage | 45,000 sample records (rotating buffer) including particle count data, environmental data, locations, annotations, and times. Scrollable on screen or printout.times. Scrollable on screen or printout |
Sample Time | 1 second to 99 hours |
Power | 110 to 240 VAC 50/60 Hz universal in-line power supply |
Operating Conditions | 41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing |
Storage Conditions | 32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing |
Warranty | 2 year limited warranty. Extended warranties available. |